{"id":5381,"date":"2019-11-27T17:50:22","date_gmt":"2019-11-27T15:50:22","guid":{"rendered":"https:\/\/www.m-i-t.co.za\/product\/microwave-digestion\/"},"modified":"2020-10-05T16:37:09","modified_gmt":"2020-10-05T14:37:09","slug":"microwave-digestion","status":"publish","type":"product","link":"https:\/\/mit-group.kz\/ru\/product\/microwave-digestion\/","title":{"rendered":"\u041c\u0438\u043a\u0440\u043e\u0432\u043e\u043b\u043d\u043e\u0432\u043e\u0435 \u043f\u0438\u0449\u0435\u0432\u0430\u0440\u0435\u043d\u0438\u0435"},"content":{"rendered":"<section class=\"wpb-content-wrapper\"><p>The Transform series of Microwave Digesters comes with a top-loading pressure-resistant heavy-duty oven chamber, safeguarding the operator under the most strenuous of circumstances.<\/p>\n<p>The Transform 800 Microwave Digestion system with its 800-psi operating pressure ensures all sample preparation for elemental analysis is conducted in the quickest time possible.\r\n\t<section class=\"vc_row wpb_row vc_row-fluid vc-zozo-section typo-dark\"><div class=\"zozo-vc-main-row-inner vc-normal-section\"><div class=\"wpb_column vc_main_column vc_column_container vc_col-sm-12 typo-default\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_tta-container\" data-vc-action=\"collapse\"><div class=\"vc_general vc_tta vc_tta-tabs vc_tta-color-white vc_tta-style-outline vc_tta-shape-square vc_tta-spacing-1 vc_tta-tabs-position-top vc_tta-controls-align-left\"><div class=\"vc_tta-tabs-container\"><ul class=\"vc_tta-tabs-list\"><li class=\"vc_tta-tab vc_active\" data-vc-tab><a href=\"#1565876727318-b778d4cc-74d6\" data-vc-tabs data-vc-container=\".vc_tta\"><span class=\"vc_tta-title-text\">TRANSFORM 680 Microwave<\/span><\/a><\/li><li class=\"vc_tta-tab\" data-vc-tab><a href=\"#1565876727331-353008a5-2809\" data-vc-tabs data-vc-container=\".vc_tta\"><span class=\"vc_tta-title-text\">TRANSFORM 800 Microwave<\/span><\/a><\/li><\/ul><\/div><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel vc_active\" id=\"1565876727318-b778d4cc-74d6\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title\"><a href=\"#1565876727318-b778d4cc-74d6\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">TRANSFORM 680 Microwave<\/span><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h5><strong>680 Details<\/strong><\/h5>\n<p>The TRANSFORM 680 Microwave Digestion System is a top-loading, closed vessel system with high-pressure capabilities to enhance the digestion quality while decreasing the overall sample preparation time. The 680 Microwave Digestion system is capable of simultaneously running up to 6 high-pressure closed vessels on a rotating carousel to ensure an even distribution of conditions, providing a fast and pre-programmed method of digestion for even the most difficult of samples. With one-step operation and full computer control of temperature and power, this system compliments your Atomic Absorption (AA), ICP-AES, and ICP-MS applications.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h5><strong>Specifications<\/strong><\/h5>\n<ul>\n<li>Number of Vessels: 6 (5 standard + 1 sensor vessel)<\/li>\n<li>Operating Pressure: 400psi<\/li>\n<li>Operating Temperature: 250\u00b0C<\/li>\n<li>Temperature Sensor: 1<\/li>\n<li>Vessel Volume: 60 mL<\/li>\n<li>Electrical: 220 V, 50\/60 Hz, 10 A<\/li>\n<li>Microwave Power: 1200 W<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h5><strong>Features and Benefits<\/strong><\/h5>\n<p>Safety First: The Transform series is top loaded, adding an extra level of security compared to front loading digestors. The safety interlock acts as a pressure and temperature sensor which automatically shuts down if any critical conditions are detected.<\/p>\n<p>Robust: Both the vessels and chambers are lined with Teflon, meaning there are no restrictions on how strong an acid or base can be used, this system can handle Hydrofluoric Acid digestion with ease.<\/p>\n<p>Real Time Monitoring: The software allows the operator to be able to constantly monitor the process of the digestion with real-time updates from the reference vessel.<\/p>\n<p>Shorter Digestions: Due to the closed spinning carousel nature of the TRANSFORM MW680, conditions are spread uniformly throughout the oven cavity, meaning less time is dedicated to conducting sample preparation and more to receiving results.<\/p>\n<p>Durable: 2 inches of stainless steel and an inner spring loaded lid makes this microwave a fortress to the stressful conditions within. If substantial pressure builds these act as the first line of defense for the operator.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h5><strong>Independently Validated<\/strong><\/h5>\n<p>Jaiswal A.K. has published to the Journal of Forensic Sciences using the Microwave Digestion TRANSFORM 680 for determining mercury levels in blood. View the full journal validation to see how the TRANFORM 680 Microwave is being used within blood samples.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"1565876727331-353008a5-2809\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title\"><a href=\"#1565876727331-353008a5-2809\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">TRANSFORM 800 Microwave<\/span><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><strong>800 Details<\/strong><\/p>\n<p>The TRANSFORM 800 Microwave Digestion System is a top-loading, closed vessel system with high-pressure capabilities to enhance the digestion quality while decreasing the overall sample preparation time.<\/p>\n<p>The TRANSFORM 800 Microwave Digestion system is capable of simultaneously running up to 10 high-pressure closed vessels on a rotating carousel to ensure an even distribution of temperature and pressure, providing a fast and pre-programmed method of digestion for even the most difficult of digestions.<\/p>\n<p>With one-step operation and full software control of temperature and power, this system compliments your Atomic Absorption (AA), ICP-AES, and ICP-MS applications whilst leading the way in optimum performance and industrial safety.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><strong>Features and Benefits<\/strong><\/p>\n<p>Safety First: The Transform series is top loaded, adding an extra level of security compared to front loading digestors. The safety interlock acts as a pressure and temperature sensor which automatically shuts down if any critical conditions are detected.<\/p>\n<p>Robust: Both the vessels and chambers are lined with Teflon, meaning there are no restrictions on how strong an acid or base can be used, this system can handle Hydrofluoric Acid digestion with ease<\/p>\n<p>Real Time Monitoring: The software allows the operator to be able to constantly monitor the process of the digestion with real-time updates from the reference vessel.<\/p>\n<p>Shorter Digestions: Due to the closed spinning carousel nature of the TRANSFORM MW800, conditions are spread uniformly throughout the oven cavity, meaning less time is dedicated to conducting sample preparation and more to receiving results.<\/p>\n<p>Durable: 2 inches of stainless steel and an inner spring loaded lid makes this microwave a fortress to the stressful conditions within. If substantial pressure builds these act as the first line of defense for the operator.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h5><strong>Specifications<\/strong><\/h5>\n<ul>\n<li>Number of Vessels: 10 (9 standard + 1 sensor vessel)<\/li>\n<li>Operating Pressure: 800psi<\/li>\n<li>Operating Temperature: 250\u00b0C<\/li>\n<li>Temperature Sensor: 1<\/li>\n<li>Vessel Volume: 50 mL<\/li>\n<li>Electrical: 220 V, 50\/60 Hz, 10 A<\/li>\n<li>Microwave Power: 1200 W<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4><strong>Independently Validated<\/strong><\/h4>\n<h5>Sudhir Chandra Saragia has published in the Journal of Epilepsy Research using the Microwave Digestion TRANSFORM 800 for determining trace elements levels in epileptic patients.<\/h5>\n<h5>View the full journal validation to see how the TRANSFORM 800 Microwave is being used within antiepileptic therapy.<\/h5>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/section>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Quick, Easy, and Safe Solutions for Microwave Digestion Systems Aurora\u2019s Transform series of Microwave Digestion systems are built with safety as the utmost concern.<\/p>\n<p>&nbsp;<\/p>","protected":false},"featured_media":5892,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_cat":[64,70,89],"product_tag":[125],"_links":{"self":[{"href":"https:\/\/mit-group.kz\/ru\/wp-json\/wp\/v2\/product\/5381"}],"collection":[{"href":"https:\/\/mit-group.kz\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/mit-group.kz\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/mit-group.kz\/ru\/wp-json\/wp\/v2\/comments?post=5381"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mit-group.kz\/ru\/wp-json\/wp\/v2\/media\/5892"}],"wp:attachment":[{"href":"https:\/\/mit-group.kz\/ru\/wp-json\/wp\/v2\/media?parent=5381"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/mit-group.kz\/ru\/wp-json\/wp\/v2\/product_cat?post=5381"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/mit-group.kz\/ru\/wp-json\/wp\/v2\/product_tag?post=5381"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}